HomeScaffolding Ticket Test AUQuestions 21–30
Basic Scaffolding Ticket (Australia)Part 3 of 3

Basic Scaffolding Ticket (Australia) Exam Questions & Answers 2026 (21–30)

Basic Scaffolding Ticket (Australia) practice questions and answers 2026. Tap an option to test yourself — you'll see the correct answer and a plain-English explanation for every question. Free, no login.

Practise Basic Scaffolding Ticket (Australia) questions free, download the PDF, or unlock timed mock exams when you are ready.
Download PDFWatch video
Multiple choice — pick the best answer, then reveal it
  1. Q21'System scaffolding' (modular scaffold) differs from tube and coupler scaffolding because:

    • AIt cannot be used above 4 metres
    • BIt does not require a licence to erect
    • CIt uses pre-engineered components with predetermined connection points, offering faster erection and consistent geometry
    • DIt is only suitable for internal use
    Show answer

    ✓ Correct answer: C. It uses pre-engineered components with predetermined connection points, offering faster erection and consistent geometry

    Topic: Components And Types

  2. Q22Which component prevents a scaffold from swaying in the plane parallel to the building face?

    • ATransoms
    • BLongitudinal (facade) bracing
    • CBase plates
    • DToe boards
    Show answer

    ✓ Correct answer: B. Longitudinal (facade) bracing

    Topic: Components And Types

  3. Q23What is the function of 'plan bracing' in scaffolding?

    • ATo support loads from above
    • BTo carry out the handover inspection
    • CTo anchor the scaffold to the building
    • DTo resist horizontal forces in the plan (horizontal) plane, preventing racking at each lift level
    Show answer

    ✓ Correct answer: D. To resist horizontal forces in the plan (horizontal) plane, preventing racking at each lift level

    Topic: Components And Types

  4. Q24A 'coupler' (clamp) used in tube and coupler scaffolding must be:

    • ACompliant with AS 1576 and free from visible defects such as cracks, distortion, or damaged threads
    • BColour-coded by the hire company
    • CMade only of aluminium
    • DTightened by hand — not with a spanner
    Show answer

    ✓ Correct answer: A. Compliant with AS 1576 and free from visible defects such as cracks, distortion, or damaged threads

    Topic: Components And Types

  5. Q25What is a 'swivel coupler' used for?

    • AConnecting two tubes at 90°
    • BConnecting the standard to the base plate
    • CConnecting two tubes at any angle for bracing
    • DLifting tube sections into position
    Show answer

    ✓ Correct answer: C. Connecting two tubes at any angle for bracing

    Topic: Components And Types

  6. Q26A 'right-angle coupler' (also called a load-bearing coupler) is used:

    • AOnly for diagonal braces
    • BTo connect ledgers and transoms to standards at 90°, and transfers load through the coupler
    • COnly on external scaffolds
    • DTo join two tubes end-to-end
    Show answer

    ✓ Correct answer: B. To connect ledgers and transoms to standards at 90°, and transfers load through the coupler

    Topic: Components And Types

  7. Q27Scaffold boards must comply with:

    • AThe site manager's preference
    • BAS 2082 (structural timber)
    • CNo specific standard — any timber can be used
    • DAS 1577 (scaffold planks) or be steel/aluminium decking rated for the required load
    Show answer

    ✓ Correct answer: D. AS 1577 (scaffold planks) or be steel/aluminium decking rated for the required load

    Topic: Components And Types

  8. Q28The maximum overhang of a scaffold board beyond its support (transom) is:

    • A4 times the board thickness (typically up to about 150 mm for a 38 mm board)
    • B1 metre
    • C500 mm regardless of thickness
    • DNo limit if the board is tied
    Show answer

    ✓ Correct answer: A. 4 times the board thickness (typically up to about 150 mm for a 38 mm board)

    Topic: Components And Types

  9. Q29What is a 'spigot' used for in system scaffolding?

    • AConnecting bracing diagonals
    • BAligning base plates
    • CJoining two standard tubes end-to-end (top-to-bottom connection)
    • DAttaching the guardrail post
    Show answer

    ✓ Correct answer: C. Joining two standard tubes end-to-end (top-to-bottom connection)

    Topic: Components And Types

  10. Q30Aluminium scaffold components must not be used:

    • AAbove 10 metres
    • BIn environments where they contact substances that attack aluminium (e.g. strong alkalis in wet cement)
    • COn any construction site
    • DIn windy conditions
    Show answer

    ✓ Correct answer: B. In environments where they contact substances that attack aluminium (e.g. strong alkalis in wet cement)

    Topic: Components And Types

Free practice here. Timed mocks when you are ready.

Use the free Scaffolding Ticket Test AU sample, download the PDF, then unlock web-based timed mock exams for a full exam rehearsal.

Download PDFStart practice test