EPA Section 608 Refrigerant Exam Questions & Answers 2026 (21–30)

EPA Section 608 Refrigerant practice questions and answers 2026. Tap an option to test yourself — you'll see the correct answer and a plain-English explanation for every question. Free, no login.

Practise EPA Section 608 Refrigerant questions free, download the PDF, or unlock timed mock exams when you are ready.
Download PDFWatch video
Multiple choice — pick the best answer, then reveal it
  1. Q21Owners of appliances normally containing 50 pounds or more of refrigerant must:

    • AVent leaks immediately
    • BKeep records of refrigerant added and repair leaks above the threshold
    • CReplace the system yearly
    • DStop using the appliance
    Show answer

    ✓ Correct answer: B. Keep records of refrigerant added and repair leaks above the threshold

    Owners and operators of appliances with a full charge of 50 pounds or more must keep servicing records and must repair leaks that exceed the applicable annual leak-rate threshold within the required time.

  2. Q22Under the current leak-repair rule, the annual leak-rate trigger for comfort-cooling appliances is:

    • A10%
    • B20%
    • C30%
    • D50%
    Show answer

    ✓ Correct answer: A. 10%

    For comfort-cooling appliances with a charge of 50 pounds or more, leaks must be repaired when the annual leak rate exceeds 10%. (Commercial refrigeration is 20% and industrial process refrigeration is 30%.)

  3. Q23Under the current leak-repair rule, the annual leak-rate trigger for commercial refrigeration is:

    • A5%
    • B10%
    • C20%
    • D35%
    Show answer

    ✓ Correct answer: C. 20%

    Commercial refrigeration appliances with a 50-pound-or-greater charge must have leaks repaired when the annual leak rate exceeds 20%.

  4. Q24The international treaty that phases out the production of ozone-depleting substances is the:

    • AKyoto Protocol
    • BMontreal Protocol
    • CParis Agreement
    • DGeneva Convention
    Show answer

    ✓ Correct answer: B. Montreal Protocol

    The Montreal Protocol is the international agreement under which nations phase out the production and consumption of ozone-depleting substances such as CFCs and HCFCs.

  5. Q25When recovering refrigerant into a recovery cylinder, you must:

    • AFill it completely
    • BWeigh it and never exceed 80% capacity
    • CHeat it above 150°F
    • DVent the non-condensables to air
    Show answer

    ✓ Correct answer: B. Weigh it and never exceed 80% capacity

    Recovery cylinders must be weighed so they are never filled beyond 80% of capacity. Overfilling leaves no room for liquid expansion and can cause the cylinder to rupture. A float or scale shutoff helps prevent overfilling.

  6. Q26Recovered refrigerant of an unknown or mixed type should be:

    • AReused in any system
    • BSold as virgin refrigerant
    • CSent for reclamation or destruction, never reused
    • DVented slowly
    Show answer

    ✓ Correct answer: C. Sent for reclamation or destruction, never reused

    Mixed or contaminated refrigerant cannot be identified or cleaned to spec on site. It must be sent off for reclamation or destruction; it must never be vented or charged into a system.

  7. Q27The substitute-refrigerant program that reviews and lists acceptable alternatives is called:

    • ASNAP
    • BSEER
    • CODP
    • DGWP
    Show answer

    ✓ Correct answer: A. SNAP

    EPA's Significant New Alternatives Policy (SNAP) program evaluates and lists substitutes for ozone-depleting substances as acceptable or unacceptable for specific end uses.

  8. Q28Which property describes how much a refrigerant contributes to thinning the ozone layer?

    • AGWP
    • BODP
    • CSEER
    • DTXV
    Show answer

    ✓ Correct answer: B. ODP

    Ozone-Depletion Potential (ODP) measures a substance's ability to destroy stratospheric ozone, relative to CFC-11 which has an ODP of 1.0. Global-Warming Potential (GWP) is a separate measure of climate impact.

  9. Q29An access (piercing/saddle) valve installed to recover from a sealed system that has no service port should be:

    • ALeft on permanently with no concern
    • BLeak-checked, because it can be a long-term leak source
    • CUsed only on low-pressure chillers
    • DFilled with oxygen first
    Show answer

    ✓ Correct answer: B. Leak-checked, because it can be a long-term leak source

    Saddle/piercing valves can leak over time. After use they should be leak-checked, and many technicians remove or properly seal them rather than leaving an unreliable long-term connection.

  10. Q30Technician certification under Section 608 is:

    • AValid for two years only
    • BDoes not expire
    • CRenewed every year
    • DOnly valid in one state
    Show answer

    ✓ Correct answer: B. Does not expire

    EPA Section 608 technician certification does not expire and is valid nationwide. There is no renewal requirement under the current rule.

Free practice here. Timed mocks when you are ready.

Use the free EPA 608 HVAC Test sample, download the PDF, then unlock web-based timed mock exams for a full exam rehearsal.

Download PDFStart practice test