  1. Q11A home inspector observes that the metallic water supply piping does not extend at least 10 feet into the earth. According to the NEC, this means:

    • AThe water pipe still qualifies as the sole grounding electrode
    • BThe water pipe cannot be used as a grounding electrode at all
    • CThe water pipe alone is not sufficient and a supplemental electrode must also be installed
    • DThe inspector must require replacement of all piping
    Show answer

    ✓ Correct answer: C. The water pipe alone is not sufficient and a supplemental electrode must also be installed

    NEC 250.52(A)(1) allows interior metal water piping as a grounding electrode only when it is electrically continuous and in contact with the earth for at least 10 feet. If it is not, a supplemental electrode is required.

    Topic: Electrical Systems

  2. Q12What is the maximum number of overcurrent devices (circuit breakers) permitted in a residential panelboard?

    • A100
    • B200
    • CNo more than the panel's ampere rating divided by 15
    • DThe number listed on the panel's label by the manufacturer
    Show answer

    ✓ Correct answer: D. The number listed on the panel's label by the manufacturer

    The maximum number of overcurrent devices is determined by the panel's listing and label. Modern NEC editions removed the old '42-circuit' rule; the panel label (e.g., 'Maximum 40 circuits') governs.

    Topic: Electrical Systems

  3. Q13A home inspector finds a Federal Pacific Electric (FPE) Stab-Lok panel. The correct reporting approach is to:

    • AReport it as compliant if no breakers appear tripped
    • BNote it as a safety concern and recommend evaluation by a licensed electrician
    • CRequire immediate replacement before occupancy
    • DTest every breaker and report only those that fail
    Show answer

    ✓ Correct answer: B. Note it as a safety concern and recommend evaluation by a licensed electrician

    FPE Stab-Lok panels have documented reliability concerns including failure to trip under overload. Home inspectors should note this as a safety concern and recommend further evaluation by a qualified electrician, without performing electrical testing themselves.

    Topic: Electrical Systems

  4. Q14Unused knockout openings in an electrical panel must be:

    • ALeft open for ventilation
    • BCovered with tape
    • CSealed with appropriate filler plates
    • DMarked with a warning sticker
    Show answer

    ✓ Correct answer: C. Sealed with appropriate filler plates

    NEC 408.7 requires all unused openings in panelboards to be effectively closed to prevent foreign objects or accidental contact with live parts, using listed closures designed for that purpose.

    Topic: Electrical Systems

  5. Q15A 240-volt, 2-pole breaker in a panel is supplying a circuit, but the inspector notices the breaker handle is not tied together. What is the concern?

    • AA fault on one leg may not simultaneously disconnect both legs, leaving one leg energized
    • BThe breaker will not provide overload protection
    • CThe voltage will be reduced to 120 volts
    • DThe circuit will be de-energized when only one leg trips
    Show answer

    ✓ Correct answer: A. A fault on one leg may not simultaneously disconnect both legs, leaving one leg energized

    Two-pole breakers for 240-volt circuits must have their handles tied so that a fault on either pole trips both simultaneously. An un-tied pair could leave one 120-volt leg energized after a fault, creating a shock hazard.

    Topic: Electrical Systems

  6. Q16During an inspection, a home inspector observes that the service panel is installed in a bathroom. Under the NEC, this installation is:

    • AAcceptable if the panel is GFCI-protected
    • BAcceptable if it is a subpanel only
    • CAcceptable if the panel has a weatherproof cover
    • DNot permitted — panelboards are prohibited in bathrooms
    Show answer

    ✓ Correct answer: D. Not permitted — panelboards are prohibited in bathrooms

    NEC 240.24(E) prohibits overcurrent devices (including panelboards) from being located in bathrooms due to the risk of shock in a wet environment. This applies to both main panels and subpanels.

    Topic: Electrical Systems

  7. Q17A standard 15-amp household branch circuit is typically wired with which wire gauge?

    • A12 AWG
    • B14 AWG
    • C10 AWG
    • D16 AWG
    Show answer

    ✓ Correct answer: B. 14 AWG

    14 AWG copper wire has an ampacity of 15 amps when protected by a 15-amp breaker. A 20-amp circuit requires 12 AWG, and a 30-amp circuit typically uses 10 AWG.

    Topic: Electrical Systems

  8. Q18Which of the following is typically a 240-volt dedicated circuit in a home?

    • ARefrigerator circuit
    • BLighting circuit
    • CElectric clothes dryer circuit
    • DDishwasher circuit
    Show answer

    ✓ Correct answer: C. Electric clothes dryer circuit

    Electric clothes dryers require 240 volts and typically a 30-amp dedicated circuit (NEMA 10-30 or 14-30 outlet). Most kitchen appliances and lighting circuits operate on 120 volts.

    Topic: Electrical Systems

  9. Q19The National Electrical Code requires at least two 20-amp small appliance branch circuits in a kitchen. These circuits must serve:

    • AOnly the countertop receptacles in the kitchen and dining area
    • BAll receptacles throughout the home
    • COnly the refrigerator and microwave
    • DAny receptacle within 6 feet of a sink
    Show answer

    ✓ Correct answer: A. Only the countertop receptacles in the kitchen and dining area

    NEC 210.11(C)(1) requires a minimum of two 20-amp small appliance circuits that serve only the receptacles in the kitchen, pantry, breakfast room, and dining room countertop areas—not other areas of the home.

    Topic: Electrical Systems

  10. Q20A dedicated 20-amp laundry branch circuit is required by the NEC to serve:

    • AOnly the washer receptacle
    • BBoth the washer and dryer on one circuit
    • CAll receptacles within 6 feet of the washer
    • DAt least one receptacle in the laundry area, with no other outlets on the circuit
    Show answer

    ✓ Correct answer: D. At least one receptacle in the laundry area, with no other outlets on the circuit

    NEC 210.11(C)(2) requires one 20-amp dedicated circuit for laundry receptacles. This circuit must serve only laundry area receptacles to ensure the washer has adequate power without sharing with other loads.

    Topic: Electrical Systems