Q11A home inspector observes that the metallic water supply piping does not extend at least 10 feet into the earth. According to the NEC, this means:
✓ Correct answer: C. The water pipe alone is not sufficient and a supplemental electrode must also be installed
NEC 250.52(A)(1) allows interior metal water piping as a grounding electrode only when it is electrically continuous and in contact with the earth for at least 10 feet. If it is not, a supplemental electrode is required.
Topic: Electrical Systems
Q12What is the maximum number of overcurrent devices (circuit breakers) permitted in a residential panelboard?
✓ Correct answer: D. The number listed on the panel's label by the manufacturer
The maximum number of overcurrent devices is determined by the panel's listing and label. Modern NEC editions removed the old '42-circuit' rule; the panel label (e.g., 'Maximum 40 circuits') governs.
Topic: Electrical Systems
Q13A home inspector finds a Federal Pacific Electric (FPE) Stab-Lok panel. The correct reporting approach is to:
✓ Correct answer: B. Note it as a safety concern and recommend evaluation by a licensed electrician
FPE Stab-Lok panels have documented reliability concerns including failure to trip under overload. Home inspectors should note this as a safety concern and recommend further evaluation by a qualified electrician, without performing electrical testing themselves.
Topic: Electrical Systems
Q14Unused knockout openings in an electrical panel must be:
✓ Correct answer: C. Sealed with appropriate filler plates
NEC 408.7 requires all unused openings in panelboards to be effectively closed to prevent foreign objects or accidental contact with live parts, using listed closures designed for that purpose.
Topic: Electrical Systems
Q15A 240-volt, 2-pole breaker in a panel is supplying a circuit, but the inspector notices the breaker handle is not tied together. What is the concern?
✓ Correct answer: A. A fault on one leg may not simultaneously disconnect both legs, leaving one leg energized
Two-pole breakers for 240-volt circuits must have their handles tied so that a fault on either pole trips both simultaneously. An un-tied pair could leave one 120-volt leg energized after a fault, creating a shock hazard.
Topic: Electrical Systems
Q16During an inspection, a home inspector observes that the service panel is installed in a bathroom. Under the NEC, this installation is:
✓ Correct answer: D. Not permitted — panelboards are prohibited in bathrooms
NEC 240.24(E) prohibits overcurrent devices (including panelboards) from being located in bathrooms due to the risk of shock in a wet environment. This applies to both main panels and subpanels.
Topic: Electrical Systems
Q17A standard 15-amp household branch circuit is typically wired with which wire gauge?
✓ Correct answer: B. 14 AWG
14 AWG copper wire has an ampacity of 15 amps when protected by a 15-amp breaker. A 20-amp circuit requires 12 AWG, and a 30-amp circuit typically uses 10 AWG.
Topic: Electrical Systems
Q18Which of the following is typically a 240-volt dedicated circuit in a home?
✓ Correct answer: C. Electric clothes dryer circuit
Electric clothes dryers require 240 volts and typically a 30-amp dedicated circuit (NEMA 10-30 or 14-30 outlet). Most kitchen appliances and lighting circuits operate on 120 volts.
Topic: Electrical Systems
Q19The National Electrical Code requires at least two 20-amp small appliance branch circuits in a kitchen. These circuits must serve:
✓ Correct answer: A. Only the countertop receptacles in the kitchen and dining area
NEC 210.11(C)(1) requires a minimum of two 20-amp small appliance circuits that serve only the receptacles in the kitchen, pantry, breakfast room, and dining room countertop areas—not other areas of the home.
Topic: Electrical Systems
Q20A dedicated 20-amp laundry branch circuit is required by the NEC to serve:
✓ Correct answer: D. At least one receptacle in the laundry area, with no other outlets on the circuit
NEC 210.11(C)(2) requires one 20-amp dedicated circuit for laundry receptacles. This circuit must serve only laundry area receptacles to ensure the washer has adequate power without sharing with other loads.
Topic: Electrical Systems