Q21What is an electrified mortise lock?
✓ Correct answer: D. A mortise lock body with an electrically actuated latch or deadbolt, allowing remote locking and unlocking
An electrified mortise lock is a traditional mortise lock body that has been fitted with an electric actuator, allowing the latch or deadbolt to be controlled electronically by an access control system while retaining all the mechanical functionality of a standard mortise lock.
Topic: Electronic Access Control
Q22Which type of electric locking device is most appropriate for a door requiring ADA-compliant egress with no key or action required to exit?
✓ Correct answer: A. Electromagnetic lock with a push-plate request-to-exit sensor
An electromagnetic lock paired with a push-plate (or motion-sensing) request-to-exit (REX) device allows compliant, hands-free or single-action egress, meeting ADA requirements that doors on accessible egress paths not require tight grasping, pinching, or twisting.
Topic: Electronic Access Control
Q23What is the typical holding force of a standard single-door electromagnetic lock?
✓ Correct answer: B. 1,200 lbs (544 kg)
Standard single-door electromagnetic locks typically have a holding force of approximately 1,200 lbs (544 kg). Heavy-duty or dual-mag configurations can exceed this, while smaller models may have lower ratings.
Topic: Electronic Access Control
Q24What is the standard low-voltage DC power supply used for most electronic access control devices?
✓ Correct answer: C. 12V or 24V DC
Most electronic access control devices, including readers, controllers, and electric locking hardware, operate on 12V DC or 24V DC. These voltages are standard in the security industry and are safe for low-voltage work.
Topic: Electronic Access Control
Q25A UPS (Uninterruptible Power Supply) is used in access control systems primarily to:
✓ Correct answer: D. Maintain system operation during a primary power failure
A UPS provides backup power, typically from batteries, to keep the access control system (controllers, readers, and locks) operational during a mains power failure, maintaining security and compliance with life-safety egress requirements.
Topic: Electronic Access Control
Q26When sizing a power supply for an access control system, which calculation is most critical?
✓ Correct answer: A. The total current draw of all connected devices at peak load
The power supply must be rated to supply enough current (amperage) to all connected devices simultaneously at peak load. Undersized power supplies cause voltage drops, leading to intermittent operation or hardware damage.
Topic: Electronic Access Control
Q27When running a power supply cable for an electromagnetic lock over a long distance, which effect must be accounted for?
✓ Correct answer: B. Voltage drop due to cable resistance, which can reduce the lock's holding force
Resistance in long cable runs causes voltage drop (V = I × R), which reduces the voltage reaching the electromagnetic lock. If the voltage drops below the lock's operating threshold, it may lose significant holding force or fail to lock securely.
Topic: Electronic Access Control
Q28What is the purpose of a Request-to-Exit (REX) device in an access control system?
✓ Correct answer: C. To signal the access control system that someone is legitimately exiting, preventing a door-forced alarm
A Request-to-Exit (REX) device (such as a push button, motion sensor, or push plate) signals the access control system before the door opens from the inside, suppressing any door-forced or door-ajar alarm and optionally releasing an electric strike or mag-lock.
Topic: Electronic Access Control
Q29A passive infrared (PIR) motion sensor used as a REX device is most likely to cause a nuisance alarm in which scenario?
✓ Correct answer: D. When the sensor detects motion outside the door and triggers an unintended unlock
A PIR-based REX sensor mounted near a glass door or improperly aimed can detect movement on the exterior (e.g., people walking past) and trigger an unintended unlock or suppress a door alarm, creating a security vulnerability or nuisance.
Topic: Electronic Access Control
Q30In a high-security environment, which REX method provides the best audit trail of exit events?
✓ Correct answer: A. Requiring a credential read on the exit side (two-way access control)
Requiring a credential presentation on the exit side (two-way or 'in/out' access control) creates a log entry associating a specific user with each exit event, providing a complete and auditable record of movement — something a passive sensor or button cannot do.
Topic: Electronic Access Control