HomeSurgical Tech CST Exam PrepQuestions 1–10
Surgical Tech CSTPart 1 of 3

Surgical Tech CST Exam Questions & Answers 2026 (1–10)

Surgical Tech CST practice questions and answers 2026. Tap an option to test yourself — you'll see the correct answer and a plain-English explanation for every question. Free, no login.

Practise Surgical Tech CST questions free, download the PDF, or unlock timed mock exams when you are ready.
Download PDFWatch video
Multiple choice — pick the best answer, then reveal it
  1. Q1Once a sterile field has been established, which area of a sterile gown is considered sterile?

    • AThe front from chest to sterile-field level and the sleeves to two inches above the elbow
    • BThe entire gown, front and back
    • COnly the gown's neckline and cuffs
    • DThe back of the gown from shoulders to waist
    Show answer

    ✓ Correct answer: A. The front from chest to sterile-field level and the sleeves to two inches above the elbow

    A sterile gown is considered sterile only in front from the chest to the level of the sterile field and at the sleeves from two inches above the elbow to the cuff. The back and areas below the field level are not sterile.

  2. Q2What is the minimum exposure time to achieve sterilization for wrapped items in a gravity-displacement steam sterilizer operating at 250 degrees F (121 degrees C)?

    • A3 minutes
    • B30 minutes
    • C15 minutes
    • D10 minutes
    Show answer

    ✓ Correct answer: B. 30 minutes

    Gravity-displacement steam sterilization at 250 degrees F (121 degrees C) typically requires a 30-minute exposure for wrapped items, because air removal is slower than in a prevacuum cycle. Higher temperatures (270 degrees F) shorten the required time.

  3. Q3A biological indicator used to monitor steam sterilization most commonly contains spores of which organism?

    • ABacillus atrophaeus
    • BClostridioides difficile
    • CGeobacillus stearothermophilus
    • DStaphylococcus aureus
    Show answer

    ✓ Correct answer: C. Geobacillus stearothermophilus

    Geobacillus stearothermophilus spores are used to test steam and hydrogen peroxide sterilization because they are highly heat-resistant. Bacillus atrophaeus spores are used for dry-heat and ethylene oxide processes.

  4. Q4If a circulator observes a break in sterile technique that no one else noticed, the correct action is to:

    • AIgnore it if the case is nearly finished
    • BWait until after the procedure to mention it
    • CDocument it but take no action
    • DAnnounce and correct the contamination immediately
    Show answer

    ✓ Correct answer: D. Announce and correct the contamination immediately

    Surgical conscience requires that any break in sterile technique be identified and corrected immediately, regardless of who is watching. Patient safety takes priority over convenience or embarrassment.

  5. Q5Ethylene oxide (EO) gas sterilization is most appropriate for which type of item?

    • AHeat- and moisture-sensitive plastics and electronics
    • BStainless-steel retractors
    • CCotton towels
    • DGlass beakers
    Show answer

    ✓ Correct answer: A. Heat- and moisture-sensitive plastics and electronics

    Ethylene oxide is a low-temperature chemical sterilant used for heat- and moisture-sensitive items such as plastics, electronics, and fiber-optic cables. Its drawbacks are long aeration times and toxicity.

  6. Q6Items used to set up a sterile field should be opened in what sequence relative to the time of use?

    • AAs far in advance as possible
    • BAs close as possible to the time of surgery
    • COnly when the surgeon arrives
    • DThe night before
    Show answer

    ✓ Correct answer: B. As close as possible to the time of surgery

    Sterile supplies should be opened as close as possible to the time of use to minimize the chance of airborne contamination. Prolonged exposure of an open field increases the risk of contamination.

  7. Q7When using the closed-gloving technique, the hands:

    • AExtend fully through the gown cuffs before gloving
    • BTouch the outside of the gloves directly
    • CRemain inside the gown sleeves until the gloves are positioned
    • DAre bare when the gloves are applied
    Show answer

    ✓ Correct answer: C. Remain inside the gown sleeves until the gloves are positioned

    In closed gloving, the scrubbed person keeps their hands inside the gown sleeves and manipulates the gloves through the fabric, so bare skin never contacts the sterile glove exterior. This reduces contamination risk during self-gloving.

  8. Q8An instrument that contacts intact mucous membranes but does not penetrate sterile tissue (e.g., a vaginal speculum) is classified under the Spaulding system as:

    • ACritical
    • BEnvironmental
    • CNoncritical
    • DSemicritical
    Show answer

    ✓ Correct answer: D. Semicritical

    Under the Spaulding classification, semicritical items contact mucous membranes or nonintact skin and require at minimum high-level disinfection. Critical items enter sterile tissue and require sterilization.

  9. Q9Immediate-use steam sterilization (IUSS, formerly 'flash') is acceptable when:

    • AA full set of backup instruments is unavailable and an item is needed urgently
    • BRoutinely sterilizing implants
    • CSterilizing items for the next day's cases
    • DReplacing terminal sterilization of all trays
    Show answer

    ✓ Correct answer: A. A full set of backup instruments is unavailable and an item is needed urgently

    IUSS is reserved for situations where an item is needed immediately and no sterile replacement is available, such as a dropped instrument with no backup. It should not be used for routine processing or, ideally, for implants.

  10. Q10Which statement about the edges of a sterile drape or wrapper is correct?

    • AThe entire drape is sterile
    • BA one-inch border around the edges is considered nonsterile
    • CThe edges are sterile if not touched
    • DOnly the corners are nonsterile
    Show answer

    ✓ Correct answer: B. A one-inch border around the edges is considered nonsterile

    A standard rule of sterile technique holds that a one-inch (about 2.5 cm) margin at the edge of a sterile drape or wrapper is considered nonsterile because it is closest to the nonsterile boundary.

Free practice here. Timed mocks when you are ready.

Use the free Surgical Tech CST Exam Prep sample, download the PDF, then unlock web-based timed mock exams for a full exam rehearsal.

Download PDFStart practice test